25 EATON 420 Mobile Piston Pump Technical Manual E-PUPI-TM002-E4 November 2014
Suction Port
Pressure Port
A
A
146.1
5.75( )
76.1
3.00( )
97.3
3.83( )
77.5
3.05( )
191
7.52( )
2X 218
8.58( )
(Diagnostic
Port)
72.6
2.86( )
(Diagnostic
Port)
69.1
2.72( )
Ø101.6
4.00( )
9.4
.37( )
2X 13.6
.54( )
(Case Drain)
79.2
3.12( )
(Case Drain)
72.1
2.84( )
122.2
4.81( )
87.9
3.46( )
5.1
.20( )
110.2
(4.34)
46
1.81( )
(Case Drain)
72.1
2.84( )
2X Ø
14.2
.56( )
74.7
2.94( )
For Shaft Conguration
See Separate Shaft
Installation Drawing
For Compensator Conguration See Separate Compensator
Installation Drawing
Optional
Diagnostic
Port
Optional Case Drain
Pressure Port
Suction Port
Top Case Drain
Bottom Case Drain
191
7.52
( )
2X 218
8.58
( )
Ø
101.6
4.00
( )
9.4
.37
( )
87.9
3.46
( )
5.1
.20
( )
38.1
(1.50)
41.1
(1.62)
4X .500-13 UNC-2B .77 Min.
-4X .375-16 UNC-2B .57 Min.
Pump Installation
B-mount / Rear-ported
RH Rotation
View A – A LH Rotation
.81 [20.6]
Optional Diagnostic Port
192.6 [7.58]
.81 [20.6]
Optional Diagnostic Port
205.3 [8.08]